LCD graphics displayText and mimic diagrams that display modes of operation, system parameters and alarms.10/100 BaseT ConnectionConnect the device to a network using a 10 or 100 BaseT connectionGreen modePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.Battery failure notificationProvides early-warning fault analysis on batteries enabling timely preventive maintenanceAutomatic internal bypassSupplies utility power to the connected loads in the event of a UPS power overload or fault.Scalable runtimeAllows additional run time to be quickly added as needed.Intelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replacedAutomatic restart of loads after UPS shutdownAutomatically starts up the connected equipment upon the return of utility power.Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.Network manageableProvides remote power management of the UPS over the network.InfraStruXure Manager CompatibleEnables centralized management via the APC InfraStruXure Manager.SmartSlotCustomize UPS capabilities with management cards.LED status indicatorsQuickly understand unit and power status with visual indicators.Serial connectivityProvides management of the UPS via a serial port.Plug-and-Play external batteriesEnsures clean, uninterrupted power to the loads when adding extra runtime to the UPS.Rack/Tower convertibleProtects the initial investment in the UPS when migrating from tower to rack-mount environment.Flash upgradeable firmwareInstall maintenance releases of firmware remotely using FTP.User-replaceable batteriesIncreases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.Predicitive failure notificationProvides early-warning fault analysis ensuring proactive component replacement.Disconnected battery notificationWarns when a battery is not available to provide backup power.Audible alarmsProvides notification of changing utility power and UPS power conditionsFrequency and voltage regulationGives higher application availability by correcting poor frequency and voltage conditions without using the battery.Power conditioningProtects connected loads from surges, spikes, lightning, and other power disturbances.Input power factor correctionMinimizes installation costs by enabling the use of smaller generators and cabling.Generator compatibleEnsures clean, uninterrupted power to protected equipment when generator power is used.Cold-start capableProvides temporary battery power when the utility power is out.Resettable circuit breakerEasy recovery from overloads; no need to replace a fuse.Safety-agency approvedEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Features | |
UPS topology: | Double-conversion (Online) |
Output power capacity: | 5 kVA |
Output power: | 4500 W |
Waveform: | Sine |
Input operation voltage (min): | 160 V |
Input operation voltage (max): | 275 V |
Input frequency: | 40 - 70 Hz |
Output operation voltage (min): | 220 V |
Output operation voltage (max): | 240 V |
Output frequency regulation: | 50/60 Hz |
Surge energy rating: | 480 J |
Efficiency: | 94.1% |
Crest factor: | 3:1 |
Emergency Power Off (EPO): | |
Output voltage Total Harmonic Distortion (THD): | 3% |
Noise level: | 55 dB |
Surge protection: | |
Audible alarm(s): | |
Auto-restart: | |
Ports & interfaces | |
AC outlet types: | C13 coupler, C19 coupler |
Power plug: | Terminal |
AC outlets quantity: | 10 AC outlet(s) |
Number of output IEC jumpers: | 2 |
USB port: | |
Serial interface: | |
Serial interface type: | RJ-45 |
SmartSlot: | |
Battery | |
Battery technology: | Sealed Lead Acid (VRLA) |
Battery capacity: | 845 VAh |
Typical backup time at full load: | 4 min |
Typical backup time at half load: | 11.8 min |
Battery life (max): | 5 year(s) |
Battery recharge time: | 1.5 h |
Hot-swap battery: | |
Automatic battery test: | |
Cold start: | |
Replacement battery cartridge: | APCRBC140 |
Design | |
Form factor: | Rackmount |
Product colour: | Black |
Rack capacity: | 3U |
Display type: | LCD |
International Protection (IP) code: | IP20 |
Certification: | REACH, CE, CE Mark, EAC, EN/IEC 62040-1, EN/IEC 62040-2, IRAM, NOM, VDE |
Operational conditions | |
Operating temperature (T-T): | 0 - 40 °C |
Storage temperature (T-T): | -15 - 45 °C |
Operating relative humidity (H-H): | 0 - 95% |
Storage relative humidity (H-H): | 0 - 95% |
Operating altitude: | 0 - 3000 m |
Non-operating altitude: | 0 - 15000 m |
Technical details | |
Sustainability certificates: | RoHS, ENERGY STAR |
Weight & dimensions | |
Width: | 432 mm |
Depth: | 719 mm |
Height: | 130 mm |
Weight: | 54.4 kg |
Package width: | 610 mm |
Package depth: | 960 mm |
Package height: | 330 mm |
Package weight: | 66.9 kg |
Packaging data | |
Rack mount kit: | |
Bracket: | |
Temperature sensor: | |
Quick installation guide: | |
Warranty card: | |
Logistics data | |
Products per pallet: | 6 pc(s) |
Harmonized System (HS) code: | 85078000 |
Other features | |
Packaging content: | Web/SNMP Management Card |